Product Name:
Rat Plasminogen Activator, Tissue (t-PA) ELISA Kit
Cat.#:
JL10999
Regulatory Status:
Alternative:
PLAT; T-PA; t-plasminogen activator; Alteplase; Reteplase
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.31-20ng/mL
Sensitivity:
0.12ng/mL
Specificity:
This kit recognizes Rat t-PA in samples. No significant cross-reactivity or interference between Rat t-PA and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Metabolism
Product Datasheets
| t-PA
Tissue-type plasminogen activator, short name tPA, is a protein that facilitates the breakdown of blood clots. It acts as an enzyme to convert plasminogen into its active form plasmin, the major enzyme responsible for clot breakdown. It is a serine protease found on endothelial cells lining the blood vessels. TPA is encoded by the PLAT gene.tPA can be manufactured using recombinant biotechnology techniques, producing types of recombinant tissue plasminogen activator (rtPA) such as alteplase, reteplase, and tenecteplase. These drugs are used in clinical medicine to treat embolic or thrombotic stroke, but they are contraindicated and dangerous in cases of hemorrhagic stroke and head trauma.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 20 | 10 | 5 | 2.5 | 1.25 | 0.62 | 0.31 | 0 |
OD | 2.19 | 1.61 | 1.05 | 0.66 | 0.43 | 0.29 | 0.21 | 0.07 |
Corrected OD | 2.12 | 1.54 | 0.98 | 0.59 | 0.36 | 0.22 | 0.14 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Rat t-PA spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-101 | 96 |
Plasma(n=8) | 92-105 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Rat t-PA and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 | 89-110 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
Average (%) | 94 | 98 | 108 |






Size
Quantity
Price ($)
48T


336 / 336
96T


432 / 432