Product Name:

Rat Estrogen Receptor Alpha (ERα) ELISA Kit

Cat.#:

JL26212

Regulatory Status:
Alternative:

ER-A1; ER; ESR; ESR1; ESRA; NR3A1; NR3-A1; Estrogen Receptor 1; Nuclear Receptor Subfamily 3,Group A,Member 1

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.31-20ng/mL
Sensitivity:
0.11ng/mL
Specificity:
This kit recognizes Rat ERα in samples. No significant cross-reactivity or interference between Rat ERα and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Metabolism
  • Rat Estrogen Receptor Alpha (ERα) ELISA Kit
  • Rat Estrogen Receptor Alpha (ERα) ELISA Kit
  • Rat Estrogen Receptor Alpha (ERα) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| ERα

Estrogen receptor alpha (ERα) is one of two main types of estrogen receptor, a nuclear receptor (mainly found as a chromatin-binding protein) that is activated by the sex hormone estrogen. The estrogen receptor (ER) is a ligand-activated transcription factor composed of several domains important for hormone binding, DNA binding, and activation of transcription. Accordingly, ERα is widely expressed throughout the body.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 20 10 5 2.5 1.25 0.62 0.31 0
OD 2.25 1.51 1.02 0.48 0.33 0.24 0.19 0.09
Corrected OD 2.16 1.42 0.93 0.39 0.24 0.15 0.1 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Rat ERα spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-107 104
Tissue Homogenates(n=8) 96-108 105





 

| Linearity

Samples were spiked with high concentrations of Rat ERα and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Tissue Homogenates(n=4)
1 : 2 Range (%) 84-97 88-96 90-110
Average (%) 93 92 96
1 : 4 Range (%) 89-103 87-108 105-115
Average (%) 94 98 108







 