Home > Sandwich ELISA Kits > Rat E Calcium Adhesion Protein;Epithelial Calcium Adhesion Protein (E-Cad) ELISA Kit
Product Name:
Rat E Calcium Adhesion Protein;Epithelial Calcium Adhesion Protein (E-Cad) ELISA Kit
Cat.#:
JL20795
Regulatory Status:
Alternative:
CDHE; CD324; CDH1; Arc1; ECAD; CDH-E; E-CAD; LCAM; UVO; Cadherin 1 Type 1; Uvomorulin; E-Cadherin; Calcium-Dependent Adhesion Protein, Epithelial; Liver Cell Adhesion Molecule
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.15-10ng/mL
Sensitivity:
0.08ng/mL
Specificity:
This kit recognizes Rat E-Cad in samples. No significant cross-reactivity or interference between Rat E-Cad and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenate and other biological fluids
Assay Procedure:
Research Area:
Cancer
Product Datasheets
| E-Cad
E Calcium Adhesion Protein;Epithelial Calcium Adhesion Protein (E-Cad) is a protein that is encoded by the CDH1 gene.Mutations are correlated with gastric, breast, colorectal, thyroid, and ovarian cancers. CDH1 has also been designated as CD324 (cluster of differentiation 324). It is a tumor suppressor gene.Cadherin-1 is a classical member of the cadherin superfamily. The protein is a calcium-dependent cell–cell adhesion glycoprotein composed of five extracellular cadherin repeats, a transmembrane region, and a highly conserved cytoplasmic tail. Mutations in this gene are correlated with gastric, breast, colorectal, thyroid, and ovarian cancers.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0.15 | 0 |
| OD | 2.62 | 1.7 | 0.95 | 0.56 | 0.31 | 0.21 | 0.15 | 0.08 |
| Corrected OD | 2.54 | 1.62 | 0.87 | 0.48 | 0.23 | 0.13 | 0.07 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Rat E-Cad spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 89-112 | 99 |
| Plasma(n=8) | 84-108 | 96 |
| Tissue Homogenates(n=8) | 83-113 | 95 |
| Linearity
Samples were spiked with high concentrations of Rat E-Cad and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Tissue Homogenates(n=4) | ||
| 1 : 2 | Range (%) | 86-106 | 83-111 | 83-112 |
| Average (%) | 98 | 91 | 100 | |
| 1 : 4 | Range (%) | 83-114 | 82-104 | 96-113 |
| Average (%) | 104 | 96 | 103 |
Size
Quantity
Price ($)
48T
1
280 / 280
96T
1
460 / 460