400-0066-400

Rat Complement Factor D (CFD) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Rat Complement Factor D (CFD) ELISA Kit
Product Name:

Rat Complement Factor D (CFD) ELISA Kit

Cat.#:

JL51251

Regulatory Status:
Alternative:

CF-D; DF; PFD; ADN; Adipsin; Properdin Factor D; C3 convertase activator

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
78.12-5000pg/mL
Sensitivity:
40.27pg/mL
Specificity:
This kit recognizes Rat CFD in samples. No significant cross-reactivity or interference between Rat CFD and analogues was observed.
Sample Type:
Serum, plasma and other biological fluids.
Assay Procedure:
Assay Procedure
Research Area:
Immunology
  • Rat Complement Factor D (CFD) ELISA Kit
  • Rat Complement Factor D (CFD) ELISA Kit
  • Rat Complement Factor D (CFD) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| CFD

Factor DC3 proactivator convertase, properdin factor D esterase, factor D (complement), complement factor D, CFD, adipsin) is a protein which is encoded by the CFD gene.Factor D is involved in the alternative complement pathway of the complement system where it cleaves factor B.The protein encoded by this gene is a member of the trypsin family of serine proteases secreted by adipocytes into the bloodstream. The encoded protein is a component of the alternative complement pathway best known for its role in humoral suppression of infectious agents. Finally, the encoded protein has a high level of expression in fat, suggesting a role for adipose tissue in immune system biology.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 5000 2500 1250 625 312.5 156.25 78.12 0
OD 2.42 1.71 1.08 0.65 0.47 0.36 0.25 0.08
Corrected OD 2.34 1.63 1 0.57 0.39 0.28 0.17 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Rat CFD spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-106 102





 

| Linearity

Samples were spiked with high concentrations of Rat CFD and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4)
1 : 2 Range (%) 84-95 88-97
Average (%) 91 93
1 : 4 Range (%) 88-103 87-108
Average (%) 94 98







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460
Top