Product Name:
Rat Clara Cell Protein 16 (CC16) ELISA Kit
Cat.#:
JL11398
Regulatory Status:
Alternative:
SCGB1A1; CC10; CCSP; UGB; UG; Uteroglobin; Uteroglobin; Urinary Protein 1; Clara Cell Secretory Protein; Secretoglobin Family 1A Member 1; Clara-Cell Specific 10-kD Protein
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
7.81-500pg/mL
Sensitivity:
3.35pg/mL
Specificity:
This kit recognizes Rat CC16 in samples. No significant cross-reactivity or interference between Rat CC16 and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, lung lavage fluid, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Immunology
Product Datasheets
| CC16
Clara cell protein 16 (CC16) is mainly secreted by clara cells in the pulmonary fine bronchial mucosa and is considered a biomarker of pulmonary fine bronchial injury, monitoring the integrity of the alveolar pro-capillary barrier and the permeability of the lung-blood barrier. Clara cells are the major cells in the terminal fine bronchial epithelium and are unciliated. They are already present in the small bronchi and gradually increase in number as they continue into the terminal fine bronchi. The cells are columnar, with a free surface projecting domed into the lumen, light cytoplasmic staining, and a high number of low electron density secretory granules in the apical cytoplasm of the cells.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (pg/mL) | 500 | 250 | 125 | 62.5 | 31.25 | 15.62 | 7.81 | 0 |
OD | 2.56 | 1.71 | 1.19 | 0.79 | 0.46 | 0.3 | 0.23 | 0.08 |
Corrected OD | 2.48 | 1.63 | 1.11 | 0.71 | 0.38 | 0.22 | 0.15 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Rat CC16 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-101 | 96 |
Plasma(n=8) | 92-105 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Rat CC16 and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
Average (%) | 94 | 98 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460