Product Name:
Rat Chemokine C-X3-C-Motif Receptor 1 (CX3CR1) ELISA Kit
Cat.#:
JL42172
Regulatory Status:
Alternative:
CCRL1; CMKBRL1; CMKDR1; GPR13; GPRV28; V28; Beta chemokine receptor-like 1; Fractalkine receptor; G-protein coupled receptor 13
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.074ng/mL
Specificity:
This kit recognizes Rat CX3CR1 in samples. No significant cross-reactivity or interference between Rat CX3CR1 and analogues was observed.
Sample Type:
Tissue homogenates;cell lysates and other biological fluids
Assay Procedure:
Research Area:
Immunology
Product Datasheets
| CX3CR1
CX3C motif chemokine receptor 1 (CX3CR1), also known as the fractalkine receptor or G-protein coupled receptor 13 (GPR13), is a transmembrane protein of the G protein-coupled receptor 1 (GPCR1) family and the only known member of the CX3C chemokine receptor subfamily. This endogenous ligand solely binds to CX3CR1 receptor. Interaction of CX3CR1 with CX3CL1 can mediate migration, adhesion and retention of leukocytes, because Fractalkine exists as membrane-anchored protein (mCX3CL1) as well as cleaved soluble molecule (sCX3CL1) due to proteolysis by metalloproteinases (MPPs).| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0.156 | 0 |
| OD | 2.18 | 1.57 | 1.03 | 0.62 | 0.42 | 0.32 | 0.26 | 0.1 |
| Corrected OD | 2.08 | 1.47 | 0.93 | 0.52 | 0.32 | 0.22 | 0.16 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Rat CX3CR1 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Tissue Homogenates(n=8) | 84-101 | 96 |
| Cell Lysates(n=8) | 97-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Rat CX3CR1 and diluted with Universal Diluent to produce samples with values within the range of the assay.| Tissue Homogenates(n=4) | Cell Lysates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 90-110 |
| Average (%) | 90 | 92 | |
| 1 : 4 | Range (%) | 89-103 | 105-115 |
| Average (%) | 94 | 108 |
Size
Quantity
Price ($)
48T
1
280 / 280
96T
1
460 / 460