Home > Sandwich ELISA Kits > Rat Mesencephalic Astrocyte Derived Neurotrophic Factor (MANF) ELISA Kit
Product Name:
Rat Mesencephalic Astrocyte Derived Neurotrophic Factor (MANF) ELISA Kit
Cat.#:
JL32552
Regulatory Status:
Alternative:
ARMET; ARP; Arginine Rich Mutated In Early Stage Tumors; Arginine-rich protein
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.15-10ng/mL
Sensitivity:
0.06ng/mL
Specificity:
This kit recognizes Rat MANF in samples. No significant cross-reactivity or interference between Rat MANF and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernatants and other biological fluids
Assay Procedure:
Research Area:
Neuroscience
Product Datasheets
| MANF
Mesencephalic astrocyte-derived neurotrophic factor (MANF), Arginine-rich, mutated in early-stage tumors (ARMET), or arginine-rich protein (ARP) is a protein that is encoded by the MANF housekeeping gene.This gene encodes a highly conserved protein whose function is known. The protein was initially thought to be longer at the N-terminus and to contain an arginine-rich region but transcribed evidence indicates a smaller open reading frame that does not encode the arginine tract. The presence of a specific mutation changing the previously numbered codon 50 from ATG to AGG, or deletion of that codon, has been reported in a variety of solid tumors. With the protein size correction, this codon is now identified as the initiation codon.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.62 | 0.31 | 0.15 | 0 |
| OD | 2.22 | 1.56 | 0.92 | 0.63 | 0.42 | 0.25 | 0.18 | 0.01 |
| Corrected OD | 2.14 | 1.48 | 0.84 | 0.55 | 0.34 | 0.17 | 0.1 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Rat MANF spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 96 |
| Plasma(n=8) | 92-105 | 102 |
| Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Rat MANF and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
| Average (%) | 94 | 98 | 108 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
640 / 640