400-0066-400

Rat Glycated Hemoglobin A1C (GHbA1c) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Rat Glycated Hemoglobin A1C (GHbA1c) ELISA Kit
Product Name:

Rat Glycated Hemoglobin A1C (GHbA1c) ELISA Kit

Cat.#:

JL12389

Regulatory Status:
Alternative:

Glycated haemoglobin A1c

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
1.25-80ng/mL
Sensitivity:
0.65ng/mL
Specificity:
This kit recognizes Rat GHbA1c in samples. No significant cross-reactivity or interference between Rat GHbA1c and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Metabolism
  • Rat Glycated Hemoglobin A1C (GHbA1c) ELISA Kit
  • Rat Glycated Hemoglobin A1C (GHbA1c) ELISA Kit
  • Rat Glycated Hemoglobin A1C (GHbA1c) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| GHbA1c

Glycated hemoglobin A1c (GHbA1c) is a major component of glycated hemoglobin and is widely used for screening, diagnosis, and monitoring of hyperglycemia.GHbA1c levels also reflect the progression of diabetic microvascular lesions.GHbA1c represents 70–90% of GHbA1, and is the glycated form of GHbA1. GHbA1c results from the glycosylation of the hemoglobin β chain N-terminal of proline, which reflects the plasma glucose concentration. The GHbA1c concentration is influenced primarily by both hemoglobin and plasma glucose concentration. However, studies have shown that factors such as race, age, diet, medication and concomitant diseases may also alter GHbA1c levels.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 80 40 20 10 5 2.5 1.25 0
OD 2.1 1.4 0.88 0.58 0.37 0.27 0.2 0.07
Corrected OD 2.03 1.33 0.81 0.51 0.3 0.2 0.13 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Rat GHbA1c spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 95
Plasma(n=8) 92-106 103
Cell Culture Supernates(n=8) 96-108 104





 

| Linearity

Samples were spiked with high concentrations of Rat GHbA1c and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Cell Culture Supernates(n=4)
1 : 2 Range (%) 84-95 88-95 90-110
Average (%) 91 93 96
1 : 4 Range (%) 89-103 88-108 105-114
Average (%) 94 98 107







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
280 / 280
96T
1
460 / 460
Top