400-0066-400

Rat Aryl Hydrocarbon Receptor Nuclear Translocator-like Protein 1 (ARNTL) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Rat Aryl Hydrocarbon Receptor Nuclear Translocator-like Protein 1 (ARNTL) ELISA Kit
Product Name:

Rat Aryl Hydrocarbon Receptor Nuclear Translocator-like Protein 1 (ARNTL) ELISA Kit

Cat.#:

JL52759

Regulatory Status:
Alternative:

BMAL1; BMAL1c; JAP3; MOP3; PASD3; TIC; BHLHE5; Basic-helix-loop-helix-PAS protein MOP3; Brain and muscle ARNT-like 1; Class E basic helix-loop-helix protein 5;Aryl Hydrocarbon Receptor Nuclear Translocator Like Protein

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.081ng/mL
Specificity:
This kit recognizes Rat ARNTL in samples. No significant cross-reactivity or interference between Rat ARNTL and analogues was observed.
Sample Type:
Tissue homogenates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Signal Transduction
  • Rat Aryl Hydrocarbon Receptor Nuclear Translocator-like Protein 1 (ARNTL) ELISA Kit
  • Rat Aryl Hydrocarbon Receptor Nuclear Translocator-like Protein 1 (ARNTL) ELISA Kit
  • Rat Aryl Hydrocarbon Receptor Nuclear Translocator-like Protein 1 (ARNTL) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| ARNTL

Basic helix-loop-helix ARNT-like protein 1 or aryl hydrocarbon receptor nuclear translocator-like protein 1 (ARNTL), or brain and muscle ARNT-like 1 is a protein that is encoded by the BMAL1 gene on chromosome 11, region p15.3. It's also known as MOP3, and, less commonly, bHLHe5, BMAL, BMAL1C, JAP3, PASD3, and TIC. BMAL1 encodes a transcription factor with a basic helix-loop-helix (bHLH) and two PAS domains.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 10 5 2.5 1.25 0.625 0.312 0.156 0
OD 2.04 1.61 1.23 0.84 0.53 0.35 0.23 0.08
Corrected OD 1.96 1.53 1.15 0.76 0.45 0.27 0.15 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Rat ARNTL spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Tissue Homogenates(n=8) 94-105 101





 

| Linearity

Samples were spiked with high concentrations of Rat ARNTL and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Tissue Homogenates(n=4)
1 : 2 Range (%) 88-96
Average (%) 93
1 : 4 Range (%) 87-107
Average (%) 100







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
280 / 280
96T
1
460 / 460
Top