400-0066-400

Rat Complement Component 4 (C4) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Rat Complement Component 4 (C4) ELISA Kit
Product Name:

Rat Complement Component 4 (C4) ELISA Kit

Cat.#:

JL13364

Regulatory Status:
Alternative:

C4

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
6.25-400ng/mL
Sensitivity:
3.2ng/mL
Specificity:
This kit recognizes Rat C4 in samples. No significant cross-reactivity or interference between Rat C4 and analogues was observed.
Sample Type:
Serum;plasma and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Signal Transduction
  • Rat Complement Component 4 (C4) ELISA Kit
  • Rat Complement Component 4 (C4) ELISA Kit
  • Rat Complement Component 4 (C4) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| C4

Complement component 4 (C4), is a protein involved in the intricate complement system, originating from the human leukocyte antigen (HLA) system. It serves a number of critical functions in immunity, tolerance, and autoimmunity with the other numerous components. Furthermore, it is a crucial factor in connecting the recognition pathways of the overall system instigated by antibody-antigen (Ab-Ag) complexes to the other effector proteins of the innate immune response. For example, the severity of a dysfunctional complement system can lead to fatal diseases and infections. Complex variations of it can also lead to schizophrenia.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 400 200 100 50 25 12.5 6.25 0
OD 2.52 1.96 1.38 0.97 0.55 0.31 0.19 0.08
Corrected OD 2.44 1.88 1.3 0.88 0.47 0.23 0.11 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Rat C4 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-105 102





 

| Linearity

Samples were spiked with high concentrations of Rat C4 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4)
1 : 2 Range (%) 84-95 88-96
Average (%) 93 90
1 : 4 Range (%) 89-103 87-108
Average (%) 99 102







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
260 / 260
96T
1
432 / 432
Top