Product Name:
Rat Meteorin Like Protein (METRNL) ELISA Kit
Cat.#:
JL48858
Regulatory Status:
Alternative:
Subfatin; Glial Cell Differentiation Regulator Like
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.94-60ng/mL
Sensitivity:
0.5ng/mL
Specificity:
This kit recognizes Rat METRNL in samples. No significant cross-reactivity or interference between Rat METRNL and analogues was observed.
Sample Type:
Tissue homogenates;cell lysates and other biological fluids
Assay Procedure:
Research Area:
Cardiovascular Biology
Product Datasheets
| METRNL
Meteorin-like/Meteorin-Beta (Metrnl)/IL-41, also known as subfatin and cometin, is a small (~27kDa) secreted cytokine, protein encoded by a gene called meteorin-like (METRNL).Lower serum levels of Metrnl might be a risk factor for developing coronary artery disease and type 2 diabetes mellitus. METRNL is a circulating factor that is induced in muscle after exercise and in adipose tissue upon cold exposure. Increasing circulating levels of Metrnl stimulates energy expenditure, improves glucose tolerance and the expression of genes associated with beige fat thermogenesis and anti-inflammatory cytokines. Metrnl stimulates an eosinophil-dependent increase in IL-4 expression and promotes alternative activation of adipose tissue macrophages, which are required for the increased expression of the thermogenic and anti-inflammatory gene programs in fat.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 60 | 30 | 15 | 7.5 | 3.75 | 1.88 | 0.94 | 0 |
| OD | 2.36 | 1.78 | 1.23 | 0.79 | 0.46 | 0.29 | 0.17 | 0.09 |
| Corrected OD | 2.27 | 1.69 | 1.14 | 0.7 | 0.37 | 0.2 | 0.08 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Rat METRNL spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 99 |
| Plasma(n=8) | 90-105 | 102 |
| Cell Lysates(n=8) | 96-106 | 105 |
| Linearity
Samples were spiked with high concentrations of Rat METRNL and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Lysates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
| Average (%) | 94 | 98 | 108 |
Size
Quantity
Price ($)
48T
1
280 / 280
96T
1
460 / 460