Detection Range:
1.56-100ng/mL
Sensitivity:
0.42ng/mL
Specificity:
This kit recognizes Rat GP-Ⅳ in samples. No significant cross-reactivity or interference between Rat GP-Ⅳ and analogues was observed.
Sample Type:
Tissue homogenates, cell lysates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Cell Biology
  • Rat Platelet Membrane Glycoprotein Ⅳ (GP-Ⅳ) ELISA Kit
  • Rat Platelet Membrane Glycoprotein Ⅳ (GP-Ⅳ) ELISA Kit
  • Rat Platelet Membrane Glycoprotein Ⅳ (GP-Ⅳ) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| GP-Ⅳ

Platelet glycoprotein VI (GPVI) is a glycoprotein receptor for collagen which is expressed in platelets. It is encoded by the GP6 gene.It was first cloned in 2000 by several groups including that of Martine Jandrot-Perrus from INSERM.GPVI is a 58-kD platelet membrane glycoprotein that plays a crucial role in the collagen-induced activation and aggregation of platelets. Upon injury to the vessel wall and subsequent damage to the endothelial lining, exposure of the subendothelial matrix to blood flow results in deposition of platelets. Collagen fibers are the most thrombogenic macromolecular components of the extracellular matrix, with collagen types I, III, and VI being the major forms found in blood vessels.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 100 50 25 12.5 6.25 3.12 1.56 0
OD 2.11 1.26 0.8 0.5 0.33 0.24 0.19 0.08
Corrected OD 2.03 1.18 0.72 0.42 0.25 0.16 0.11 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Rat GP-Ⅳ spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Tissue Homogenates(n=8) 84-101 96
Cell Lysates(n=8) 96-108 105





 

| Linearity

Samples were spiked with high concentrations of Rat GP-Ⅳ and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Tissue Homogenates(n=4) Cell Lysates(n=4)
1 : 2 Range (%) 84-98 90-110
Average (%) 93 96
1 : 4 Range (%) 89-103 105-115
Average (%) 94 108







 