Home > Sandwich ELISA Kits > Rat Transient Receptor Potential Cation Channel Subfamily M, Member 4 (TRPM4) ELISA Kit
Product Name:
Rat Transient Receptor Potential Cation Channel Subfamily M, Member 4 (TRPM4) ELISA Kit
Cat.#:
JL17110
Regulatory Status:
Alternative:
TRPM4B; Melastatin-4; Calcium-activated non-selective cation channel 1; Long transient receptor potential channel 4
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.079ng/mL
Specificity:
This kit recognizes Rat TRPM4 in samples. No significant cross-reactivity or interference between Rat TRPM4 and analogues was observed.
Sample Type:
tissue homogenates, cell lysates and other biological fluids
Assay Procedure:

Research Area:
Signal Transduction
Product Datasheets
| TRPM4
Transient receptor potential cation channel subfamily M member 4 (hTRPM4), also known as melastatin-4, is a protein that is encoded by the TRPM4 gene.The protein encoded by this gene is a calcium-activated nonselective ion channel that mediates transport of monovalent cations across membranes, thereby depolarizing the membrane. The activity of the encoded protein increases with increasing intracellular calcium concentration, but this channel does not transport calcium.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0.156 | 0 |
OD | 2.02 | 1.22 | 0.75 | 0.47 | 0.3 | 0.22 | 0.18 | 0.08 |
Corrected OD | 1.94 | 1.14 | 0.67 | 0.39 | 0.22 | 0.14 | 0.1 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Rat TRPM4 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Tissue Homogenates(n=8) | 91-105 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 104 |
| Linearity
Samples were spiked with high concentrations of Rat TRPM4 and diluted with Universal Diluent to produce samples with values within the range of the assay.Tissue Homogenates(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 86-96 | 90-110 |
Average (%) | 93 | 100 | |
1 : 4 | Range (%) | 87-108 | 105-115 |
Average (%) | 98 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460