400-0066-400

Rat Interleukin 19 (IL-19) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Rat Interleukin 19 (IL-19) ELISA Kit
Product Name:

Rat Interleukin 19 (IL-19) ELISA Kit

Cat.#:

JL20883

Regulatory Status:
Alternative:

MDA1; ZMDA1, IL-10C, NG.1; Melanoma Differentiation Associated Protein-Like Protein

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
15.6-1000pg/mL
Sensitivity:
7.6pg/mL
Specificity:
This kit recognizes Rat IL-19 in samples. No significant cross-reactivity or interference between Rat IL-19 and analogues was observed.
Sample Type:
Serum, plasma and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Immunology
  • Rat Interleukin 19 (IL-19) ELISA Kit
  • Rat Interleukin 19 (IL-19) ELISA Kit
  • Rat Interleukin 19 (IL-19) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| IL-19

Interleukin 19 (IL-19) is an immunosuppressive protein that belongs to the IL-10 cytokine subfamily.The IL-19 protein is composed of 159 amino acids and has a quaternary structure with alpha helix motifs and loops. IL-19 is preferentially expressed in monocytes, macrophages, and T and B lymphocytes, but interacts with immune cells (macrophages, T cells, B cells) and non-immune cells (endothelial cells and brain resident glial cells, etc).IL-19 initiates JAK-STAT signaling which activates genes and creates mRNA sequences (transcription) that are translated into proteins (translation) which have downstream effector functions.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 1000 500 250 125 62.5 31.2 15.6 0
OD 2.44 1.91 1.37 0.84 0.51 0.34 0.26 0.07
Corrected OD 2.37 1.84 1.3 0.77 0.44 0.27 0.19 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Rat IL-19 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-105 101





 

| Linearity

Samples were spiked with high concentrations of Rat IL-19 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4)
1 : 2 Range (%) 84-95 88-96
Average (%) 91 93
1 : 4 Range (%) 89-103 87-108
Average (%) 94 98







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460
Top