Product Name:
Rat Thioredoxin (Trx) ELISA Kit
Cat.#:
JL11081
Regulatory Status:
Alternative:
TXN; ADF; SASP; TRDX; TRX1; ATL-derived factor; Surface-associated sulphydryl protein
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
3.12-200ng/mL
Sensitivity:
1.15ng/mL
Specificity:
This kit recognizes Rat Trx in samples. No significant cross-reactivity or interference between Rat Trx and analogues was observed.
Sample Type:
Serum, plasma and other biological fluids
Assay Procedure:

Research Area:
Metabolism
Product Datasheets
| Trx
Thioredoxin (TRX or TXN) is a class of small redox proteins known to be present in all organisms. It plays a role in many important biological processes, including redox signaling. Thioredoxins are encoded by TXN and TXN2 genes. Loss-of-function mutation of either of the two human thioredoxin genes is lethal at the four-cell stage of the developing embryo. Although not entirely understood, thioredoxin is linked to medicine through their response to reactive oxygen species (ROS). In plants, thioredoxins regulate a spectrum of critical functions, ranging from photosynthesis to growth, flowering and the development and germination of seeds. Thioredoxins play a role in cell-to-cell communication.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 200 | 100 | 50 | 25 | 12.5 | 6.25 | 3.12 | 0 |
OD | 2.45 | 1.46 | 0.89 | 0.57 | 0.39 | 0.28 | 0.23 | 0.09 |
Corrected OD | 2.36 | 1.37 | 0.8 | 0.48 | 0.3 | 0.19 | 0.14 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Rat Trx spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-101 | 96 |
Plasma(n=8) | 92-105 | 102 |
| Linearity
Samples were spiked with high concentrations of Rat Trx and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 |
Average (%) | 91 | 92 | |
1 : 4 | Range (%) | 89-103 | 87-108 |
Average (%) | 94 | 98 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460