Product Name:
Rat Amine Oxidase, Copper Containing 3 (AOC3) ELISA Kit
Cat.#:
JL52528
Regulatory Status:
Alternative:
VAP1; HPAO; SSAO; Membrane primary amine oxidase; Vascular Adhesion Protein 1; Semicarbazide-Sensitive Amine Oxidase; Copper-Containing Amine Oxygen Oxidoreductase
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
15.6-1000pg/mL
Sensitivity:
7.6pg/mL
Specificity:
This kit recognizes Rat AOC3 in samples. No significant cross-reactivity or interference between Rat AOC3 and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates and other biological fluids
Assay Procedure:

Research Area:
Metabolism
Product Datasheets
| AOC3
Amine oxidase, copper containing 3 (AOC3), also known as vascular adhesion protein (VAP-1) and HPAO is a type 1 membrane-bound glycoprotein that has a distal adhesion domain and an enzymatically active amine oxidase site outside of the membrane. Amine oxidases are a family of enzymes that catalyze the oxidation of various endogenous amines, including histamine or dopamine. Membrane-bound VAP-1 releases an active, soluble form of the protein, which may be conducive to increased inflammation and the progression of many vascular disorders.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (pg/mL) | 1000 | 500 | 250 | 125 | 62.5 | 31.2 | 15.6 | 0 |
OD | 2.66 | 2.04 | 1.51 | 1.04 | 0.65 | 0.39 | 0.22 | 0.09 |
Corrected OD | 2.57 | 1.95 | 1.42 | 0.95 | 0.56 | 0.3 | 0.13 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Rat AOC3 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-101 | 96 |
Plasma(n=8) | 92-106 | 103 |
Cell Lysates(n=8) | 97-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Rat AOC3 and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Cell Lysates(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-95 | 90-110 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 89-103 | 88-108 | 105-114 |
Average (%) | 94 | 98 | 107 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460