Product Name:
Rat Activin A (ACV-A) ELISA Kit
Cat.#:
JL21070
Regulatory Status:
Alternative:
ACV-A; Activin Beta A Beta A Homodimer
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
31.25-2000pg/mL
Sensitivity:
11.33pg/mL
Specificity:
This kit recognizes Rat ACV-A in samples. No significant cross-reactivity or interference between Rat ACV-A and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Signal Transduction
Product Datasheets
| ACV-A
Activin A(ACVA) is a member of the TGF-β superfamily, a large family of more than 3 structurally related proteins. TGF-β superfamily cytokines play a key role in regulating tissue balance, organ development, inflammation, cell proliferation and apoptosis. In fact, it has been recognized as A multifunctional cytokine, expressed in a wide range of tissues and cells, and there is growing evidence that activin A is involved in the pathogenesis of a variety of diseases, from rheumatoid arthritis, bone disease, sepsis, inflammatory bowel disease, atherosclerosis, chronic heart failure, to certain malignancies.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (pg/mL) | 2000 | 1000 | 500 | 250 | 125 | 62.5 | 31.25 | 0 |
OD | 2.44 | 1.91 | 1.37 | 0.84 | 0.51 | 0.34 | 0.26 | 0.07 |
Corrected OD | 2.37 | 1.84 | 1.3 | 0.77 | 0.44 | 0.27 | 0.19 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Rat ACV-A spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-103 | 98 |
Plasma(n=8) | 92-105 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Rat ACV-A and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 | 90-112 |
Average (%) | 91 | 93 | 98 | |
1 : 4 | Range (%) | 89-103 | 87-108 | 105-116 |
Average (%) | 94 | 98 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T