400-0066-400

Rat Chemokine C-X-C-Motif Receptor 3 (CXCR3) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Rat Chemokine C-X-C-Motif Receptor 3 (CXCR3) ELISA Kit
Product Name:

Rat Chemokine C-X-C-Motif Receptor 3 (CXCR3) ELISA Kit

Cat.#:

JL13105

Regulatory Status:
Alternative:

CD183; CKR-L2; CMKAR3; GPR9; IP10r; IP10-R; Mig-R; MigR; G Protein-Coupled Receptor 9; Interferon-inducible protein 10 receptor; IP-10 receptor

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.15-10ng/mL
Sensitivity:
0.06ng/mL
Specificity:
This kit recognizes Rat CXCR3 in samples. No significant cross-reactivity or interference between Rat CXCR3 and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Signal Transduction
  • Rat Chemokine C-X-C-Motif Receptor 3 (CXCR3) ELISA Kit
  • Rat Chemokine C-X-C-Motif Receptor 3 (CXCR3) ELISA Kit
  • Rat Chemokine C-X-C-Motif Receptor 3 (CXCR3) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| CXCR3

Chemokine receptor CXCR3 is a Gαi protein-coupled receptor in the CXC chemokine receptor family. CXCR3 is expressed primarily on activated T lymphocytes and NK cells, and some epithelial cells. CXCR3 and CCR5 are preferentially expressed on Th1 cells, whereas Th2 cells favor the expression of CCR3 and CCR4. CXCR3 ligands that attract Th1 cells can concomitantly block the migration of Th2 cells in response to CCR3 ligands, thus enhancing the polarization of effector T cell recruitment.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 10 5 2.5 1.25 0.62 0.31 0.15 0
OD 2.48 1.65 1.07 0.71 0.45 0.28 0.19 0.09
Corrected OD 2.39 1.56 0.98 0.62 0.36 0.19 0.1 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Rat CXCR3 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 93-105 102
Tissue Homogenates(n=8) 96-108 105





 

| Linearity

Samples were spiked with high concentrations of Rat CXCR3 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Tissue Homogenates(n=4)
1 : 2 Range (%) 84-95 88-96 90-110
Average (%) 91 93 96
1 : 4 Range (%) 89-102 87-108 105-115
Average (%) 94 98 108







 