400-0066-400

Rat Pepsinogen C (PGC) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Rat Pepsinogen C (PGC) ELISA Kit
Product Name:

Rat Pepsinogen C (PGC) ELISA Kit

Cat.#:

JL23560

Regulatory Status:
Alternative:

PG-C; Progastricsin; Gastricsin

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
4.68-300ng/mL
Sensitivity:
1.35ng/mL
Specificity:
This kit recognizes Rat PGC in samples. No significant cross-reactivity or interference between Rat PGC and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Immunology
  • Rat Pepsinogen C (PGC) ELISA Kit
  • Rat Pepsinogen C (PGC) ELISA Kit
  • Rat Pepsinogen C (PGC) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| PGC

Progastricsin, also known as pepsinogen C, is the precursor of the enzyme gastrin encoded by the PGC gene. Progastricsin is an aspartic proteinase that belongs to the peptidase family A1. The encoded protein is a digestive enzyme that is produced in the stomach and constitutes a major component of the gastric mucosa. This protein is also secreted into the serum. This protein is synthesized as an inactive zymogen that includes a highly basic prosegment. This enzyme is converted into its active mature form at low pH by sequential cleavage of the prosegment that is carried out by the enzyme itself.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 300 150 75 37.5 18.75 9.37 4.68 0
OD 2.3 1.87 1.25 0.82 0.55 0.41 0.32 0.09
Corrected OD 2.21 1.78 1.16 0.73 0.46 0.32 0.23 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Rat PGC spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-105 102
Tissue Homogenates(n=8) 96-108 105





 

| Linearity

Samples were spiked with high concentrations of Rat PGC and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Tissue Homogenates(n=4)
1 : 2 Range (%) 84-95 87-96 90-110
Average (%) 91 93 96
1 : 4 Range (%) 89-103 87-108 104-115
Average (%) 94 98 108







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460