Product Name:
Rat Alkaline Phosphatase, Liver/Bone/Kidney (ALPL) ELISA Kit
Cat.#:
JL16503
Regulatory Status:
Alternative:
BALP; BSAP; HOPS; AP-TNAP; TNSALP; Bone Alkaline Phosphatase; Alkaline Phosphatase,Tissue-Nonspecific Isozyme; Alkaline Phosphatase, Liver/Bone/Kidney
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.78-50ng/mL
Sensitivity:
0.31ng/mL
Specificity:
This kit recognizes Rat ALPL in samples. No significant cross-reactivity or interference between Rat ALPL and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Cancer
Product Datasheets
| ALPL
Alkaline phosphatase(ALPL) is an enzyme encoded by the ALPL gene.The product of this gene is a membrane-bound glycosylated enzyme that is expressed in a variety of tissues and is, therefore, referred to as the tissue-nonspecific form of the enzyme.This enzyme has been linked directly to a disorder known as hypophosphatasia, a disorder that is characterized by low serum ALP and undermineralised bone (osteomalacia). There are different clinical forms of HPP which can be inherited by an autosomal recessive trait or autosomal dominant trait, the former causing more severe forms of the disease. Alkaline phosphatase allows for mineralization of calcium and phosphorus by bones and teeth.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 50 | 25 | 12.5 | 6.25 | 3.12 | 1.56 | 0.78 | 0 |
OD | 2.05 | 1.5 | 0.99 | 0.66 | 0.45 | 0.33 | 0.24 | 0.08 |
Corrected OD | 1.97 | 1.42 | 0.91 | 0.58 | 0.37 | 0.25 | 0.16 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Rat ALPL spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 85-102 | 96 |
Plasma(n=8) | 92-105 | 102 |
| Linearity
Samples were spiked with high concentrations of Rat ALPL and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 |
Average (%) | 91 | 93 | |
1 : 4 | Range (%) | 89-103 | 87-108 |
Average (%) | 94 | 98 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460