400-0066-400

Rat Coagulation Factor X (FⅩ) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Rat Coagulation Factor X (FⅩ) ELISA Kit
Product Name:

Rat Coagulation Factor X (FⅩ) ELISA Kit

Cat.#:

JL11817

Regulatory Status:
Alternative:

F10; FXA; Stuart Prower Factor; Thrombokinase

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.31-20ng/mL
Sensitivity:
0.14ng/mL
Specificity:
This kit recognizes Rat FⅩ in samples. No significant cross-reactivity or interference between Rat FⅩ and analogues was observed.
Sample Type:
Plasma
Assay Procedure:
Assay Procedure
Research Area:
Cardiovascular Biology
  • Rat Coagulation Factor X (FⅩ) ELISA Kit
  • Rat Coagulation Factor X (FⅩ) ELISA Kit
  • Rat Coagulation Factor X (FⅩ) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| FⅩ

Coagulation factor X , or Stuart factor, is an enzyme of the coagulation cascade, encoded by F1 gene. It is a serine endopeptidase that is synthesized in the liver and requires vitamin K to be synthesized. FX is activated, by hydrolysis, into factor Xa by both factor IX with its cofactor, factor VIII in a complex known as intrinsic pathway; and factor VII with its cofactor, tissue factor in a complex known as extrinsic pathway. It is therefore the first member of the final common pathway or thrombin pathway.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 20 10 5 2.5 1.25 0.62 0.31 0
OD 2.36 1.36 0.8 0.48 0.34 0.26 0.22 0.09
Corrected OD 2.27 1.27 0.71 0.39 0.25 0.17 0.13 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Rat FⅩ spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Plasma(n=8) 92-105 101





 

| Linearity

Samples were spiked with high concentrations of Rat FⅩ and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Plasma(n=4)
1 : 2 Range (%) 88-96
Average (%) 92
1 : 4 Range (%) 87-108
Average (%) 98







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460
Top