Product Name:
Pig maltase (maltase) ELISA Kit
Cat.#:
JL52103
Regulatory Status:
Alternative:
alpha-glucosidase;glucoinvertase;glucosidosucrase;maltase-glucoamylase;alpha-glucopyranosidase;glucosidoinvertase;alpha-D-glucosidase;alpha-glucoside hydrolase;alpha-1,4-glucosidase;alpha-D-glucoside glucohydrolase
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
1.56-100ng/mL
Sensitivity:
0.76ng/mL
Specificity:
This kit recognizes Pig maltase in samples. No significant cross-reactivity or interference between Pig maltase and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Metabolism
Product Datasheets
| maltase
Maltase is an informal name for a family of enzymes that catalyze the hydrolysis of disaccharide maltose into two simple sugars of glucose. Maltases are found in plants, bacteria, yeast, humans, and other vertebrates.Digestion of starch requires six intestinal enzymes. Two of these enzymes are luminal endo-glucosidases named alpha-amylases. The other four enzymes have been identified as different maltases, exo-glucosidases bound to the luminal surface of enterocytes. Two of these maltase activities were associated with sucrase-isomaltase (maltase Ib, maltase Ia). The other two maltases with no distinguishing characteristics were named maltase-glucoamylase (maltases II and III).| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 100 | 50 | 25 | 12.5 | 6.25 | 3.12 | 1.56 | 0 |
OD | 2.21 | 1.82 | 1.51 | 1.08 | 0.79 | 0.5 | 0.35 | 0.09 |
Corrected OD | 2.12 | 1.73 | 1.42 | 0.99 | 0.7 | 0.41 | 0.26 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Pig maltase spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-101 | 96 |
Plasma(n=8) | 92-105 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Pig maltase and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 | 90-111 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
Average (%) | 94 | 98 | 108 |






Size
Quantity
Price ($)
48T


396 / 396
96T


576 / 576