Product Name:
Mouse Collagenase Type Ⅳ (Ⅳ-C) ELISA Kit
Cat.#:
JL20170
Regulatory Status:
Alternative:
IV-C
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.074ng/mL
Specificity:
This kit recognizes Mouse Ⅳ-C in samples. No significant cross-reactivity or interference between Mouse Ⅳ-C and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Metabolism
Product Datasheets
| Ⅳ-C
Collagenase is a protease that consists of a single polypeptide chain of approximately 1,000 amino acid residues in length.Collagenase is capable of digesting native collagen fibers commonly found in connective tissue and is therefore often used for tissue dissociation.Collagenase preparations contain the activity of several proteases, including collagenase, caspase, clostridial protease, and trypsin (Kessler & Yaron).Type IV collagenase contains low levels of trypsin activity and is frequently used in pancreatic islets (Taguchi et al.) and in applications where receptor integrity needs to be maintained.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0.156 | 0 |
| OD | 2.52 | 1.96 | 1.38 | 0.97 | 0.55 | 0.31 | 0.19 | 0.08 |
| Corrected OD | 2.44 | 1.88 | 1.3 | 0.88 | 0.47 | 0.23 | 0.11 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Mouse Ⅳ-C spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 96 |
| Plasma(n=8) | 92-105 | 102 |
| Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Mouse Ⅳ-C and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
| Average (%) | 94 | 98 | 108 |
Size
Quantity
Price ($)
48T
1
280 / 280
96T
1
460 / 460