Product Name:
Mouse Mast Cell Protease 1 (Mcpt-1) ELISA Kit
Cat.#:
JL47291
Regulatory Status:
Alternative:
Mcpt1;Mast Cell Protease1; Mast Cell Protease-1; Mcp1; Mcp-1; MMPC-1
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.31-20ng/mL
Sensitivity:
0.17ng/mL
Specificity:
This kit recognizes Mouse Mcpt-1 in samples. No significant cross-reactivity or interference between Mouse Mcpt-1 and analogues was observed.
Sample Type:
Serum;plasma; cell lysates and other biological fluids
Assay Procedure:
Research Area:
Cardiovascular Biology
Product Datasheets
| Mcpt-1
Mast Cell Protease1 is a chymotryptic serine proteinase that belongs to the peptidase family S1. It is expressed in mast cells and thought to function in the degradation of the extracellular matrix, the regulation of submucosal gland secretion, and the generation of vasoactive peptides. In the heart and blood vessels, this protein, rather than angiotensin converting enzyme, is largely responsible for converting angiotensin I to the vasoactive peptide angiotensin II. Angiotensin II has been implicated in blood pressure control and in the pathogenesis of hypertension, cardiac hypertrophy, and heart failure.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 20 | 10 | 5 | 2.5 | 1.25 | 0.62 | 0.31 | 0 |
| OD | 2.36 | 1.78 | 1.23 | 0.79 | 0.46 | 0.29 | 0.17 | 0.09 |
| Corrected OD | 2.27 | 1.69 | 1.14 | 0.7 | 0.37 | 0.2 | 0.08 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Mouse Mcpt-1 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 96 |
| Plasma(n=8) | 92-105 | 102 |
| Cell Lysates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Mouse Mcpt-1 and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Lysates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
| Average (%) | 94 | 98 | 108 |
Size
Quantity
Price ($)
48T
1
280 / 280
96T
1
460 / 460


