Product Name:
Mouse Acetaldehyde Dehydrogenase (ALDH) ELISA Kit
Cat.#:
JL20658
Regulatory Status:
Alternative:
ALDH
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.074ng/mL
Specificity:
This kit recognizes Mouse ALDH in samples. No significant cross-reactivity or interference between Mouse ALDH and analogues was observed.
Sample Type:
Serum;plasma;cell culture supernatants and other biological fluids
Assay Procedure:
Research Area:
Stem Cells
Product Datasheets
| ALDH
Acetaldehyde dehydrogenases (EC 1.2.1.10) are dehydrogenase enzymes which catalyze the conversion of acetaldehyde into acetyl-CoA. This can be summarized as follows: Acetaldehyde + NAD+ + Coenzyme A ↔ Acetyl-CoA + NADH + H+.In the liver, ethanol is converted into acetyl CoA by a two step process. In the first step, ethanol is converted to acetaldehyde by alcohol dehydrogenase. In the second step, the acetaldehyde is converted to acetyl CoA by acetaldehyde dehydrogenase. Acetaldehyde is more toxic than alcohol and is responsible for many hangover symptoms.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0.156 | 0 |
| OD | 2.52 | 1.96 | 1.38 | 0.97 | 0.55 | 0.31 | 0.19 | 0.08 |
| Corrected OD | 2.44 | 1.88 | 1.3 | 0.88 | 0.47 | 0.23 | 0.11 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Mouse ALDH spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 96 |
| Plasma(n=8) | 92-105 | 102 |
| Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Mouse ALDH and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
| Average (%) | 94 | 98 | 108 |
Size
Quantity
Price ($)
48T
1
280 / 280
96T
1
460 / 460