Mouse Cardiac Muscle Troponin T (cTnT) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Mouse Cardiac Muscle Troponin T (cTnT) ELISA Kit
Product Name:

Mouse Cardiac Muscle Troponin T (cTnT) ELISA Kit

Cat.#:

JL40538

Regulatory Status:
Alternative:

Troponin T Type 2;Cardiac; TNNT2; CMH2; TnTc; Cardiomyopathy;Hypertrophic 2

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
15.6-1000pg/mL
Sensitivity:
7.6pg/mL
Specificity:
This kit recognizes Mouse cTnT in samples. No significant cross-reactivity or interference between Mouse cTnT and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Cardiovascular Biology
  • Mouse Cardiac Muscle Troponin T (cTnT) ELISA Kit
  • Mouse Cardiac Muscle Troponin T (cTnT) ELISA Kit
  • Mouse Cardiac Muscle Troponin T (cTnT) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| cTnT

Cardiac muscle troponin T (cTnT) is a protein that encoded by the TNNT2 gene.Cardiac TnT is the tropomyosin-binding subunit of the troponin complex, which is located on the thin filament of striated muscles and regulates muscle contraction in response to alterations in intracellular calcium ion concentration.As part of the Troponin complex, the function of cTnT is to regulate muscle contraction. The N-terminal region of TnT that strongly binds actin most likely moves with Tm and actin during strong myosin crossbridge binding and force generation. This region is likely involved in the transduction of cooperativity down the thin filament.The C-terminal region of TnT constitutes part of the globular troponin complex domain, and participates in employing the calcium sensitivity of strong myosin crossbridge binding to the thin filament.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 1000 500 250 125 62.5 31.2 15.6 0
OD 2.22 1.56 0.92 0.63 0.42 0.25 0.18 0.08
Corrected OD 2.14 1.48 0.84 0.55 0.34 0.17 0.1 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Mouse cTnT spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-107 103
Cell Culture Supernates(n=8) 96-108 105





 

| Linearity

Samples were spiked with high concentrations of Mouse cTnT and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Cell Culture Supernates(n=4)
1 : 2 Range (%) 84-95 88-96 90-110
Average (%) 91 93 96
1 : 4 Range (%) 89-103 87-108 105-115
Average (%) 94 98 108







 