Product Name:
Mouse Vinculin (VCL) ELISA Kit
Cat.#:
JL24450
Regulatory Status:
Alternative:
MVCL; Metavinculin
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.312-20ng/mL
Sensitivity:
0.151ng/mL
Specificity:
This kit recognizes Mouse VCL in samples. No significant cross-reactivity or interference between Mouse VCL and analogues was observed.
Sample Type:
Tissue homogenates;cell lysates and other biological fluids
Assay Procedure:
Research Area:
Cell Biology
Product Datasheets
| VCL
Vinculin is a 117-kDa cytoskeletal protein (1,066 amino acids) with an acidic N-terminal head and basic C-terminal tail connected by a proline-rich linker. The globular head domain binds talin and α-actinin and contains tyrosine phosphorylation sites (e.g., Y100, Y1065), while the tail interacts with F-actin, paxillin, and membrane lipids. This multidomain structure enables its role as a mechanical linker at focal adhesions and adherens junctions. Vinculin transitions between closed (auto-inhibited) and open (active) conformations to regulate cell adhesion, migration, and force transduction. Knockout models show embryonic lethality with cardiac and neural defects, underscoring its essential functions in development and tissue integrity.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 20 | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0 |
| OD | 2.22 | 1.56 | 0.92 | 0.63 | 0.42 | 0.25 | 0.18 | 0.08 |
| Corrected OD | 2.14 | 1.48 | 0.94 | 0.55 | 0.34 | 0.17 | 0.1 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Mouse VCL spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Tissue Homogenates(n=8) | 84-101 | 95 |
| Cell Lysates(n=8) | 96-108 | 104 |
| Linearity
Samples were spiked with high concentrations of Mouse VCL and diluted with Universal Diluent to produce samples with values within the range of the assay.| Tissue Homogenates(n=4) | Cell Lysates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 90-110 |
| Average (%) | 91 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 105-114 |
| Average (%) | 93 | 107 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
460 / 460