400-0066-400

Mouse Angiotensinogen (AGT) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Mouse Angiotensinogen (AGT) ELISA Kit
Product Name:

Mouse Angiotensinogen (AGT) ELISA Kit

Cat.#:

JL12297

Regulatory Status:
Alternative:

ANHU; SERPINA8; Angiotensin; Renin Substrate; Serpin Peptidase Inhibitor,Clade A,Member 8(Alpha-1 Antiproteinase,Antitrypsin)

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
7.8-500ng/mL
Sensitivity:
3.8ng/mL
Specificity:
This kit recognizes Mouse AGT in samples. No significant cross-reactivity or interference between Mouse AGT and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Cardiovascular Biology
  • Mouse Angiotensinogen (AGT) ELISA Kit
  • Mouse Angiotensinogen (AGT) ELISA Kit
  • Mouse Angiotensinogen (AGT) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| AGT

Angiotensinogen is an alpha-2-globulin synthesized in the liver that is a precursor to angiotensin, but has also been noted to have many other effects unrelated to angiotensin peptides.It is a member of the serotonin family and has another name: serum protein A8, but it is not known to inhibit other enzymes like most serotonins.Angiotensinogen is also known as a renin substrate.It is cleaved by renin at the N-terminus to produce angiotensin I, which is subsequently modified to angiotensin II. The peptide is 485 amino acids long, and when renin acts on it, the N-terminal 10 amino acids are cleaved.Plasma angiotensinogen levels are increased by plasma corticosterone, estrogen, thyroid hormone, and angiotensin II levels.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 500 250 125 62.5 31.2 15.6 7.8 0
OD 2.22 1.56 0.92 0.63 0.42 0.25 0.18 0.01
Corrected OD 2.14 1.48 0.84 0.55 0.34 0.17 0.1 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Mouse AGT spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-106 103
Cell Culture Supernates(n=8) 96-108 105





 

| Linearity

Samples were spiked with high concentrations of Mouse AGT and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Cell Culture Supernates(n=4)
1 : 2 Range (%) 84-95 88-95 90-110
Average (%) 91 92 96
1 : 4 Range (%) 89-103 87-108 105-114
Average (%) 94 98 107







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460
Top