Product Name:
Mouse Tissue Inhibitors Of Metalloproteinase 3 (TIMP3) ELISA Kit
Cat.#:
JL12402
Regulatory Status:
Alternative:
SFD; TIMP Metallopeptidase Inhibitor 3; Metallopeptidase Inhibitor 3; Sorsby Fundus Dystrophy; Pseudoinflammatory
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.31-20ng/mL
Sensitivity:
0.19ng/mL
Specificity:
This kit recognizes Mouse TIMP3 in samples. No significant cross-reactivity or interference between Mouse TIMP3 and analogues was observed.
Sample Type:
serum, plasma, tissue homogenates and other biological fluids
Assay Procedure:

Research Area:
Cancer
Product Datasheets
| TIMP3
Metalloproteinase inhibitor 3 is a protein that is encoded by the TIMP3 gene.This gene belongs to the tissue inhibitor of metalloproteinases gene family. The proteins encoded by this gene family are inhibitors of the matrix metalloproteinases, a group of peptidases involved in degradation of the extracellular matrix (ECM). Expression of this gene is induced in response to mitogenic stimulation and this netrin domain-containing protein is localized to the ECM. Mutations in this gene have been associated with the autosomal dominant disorder Sorsby's fundus dystrophy.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 20 | 10 | 5 | 2.5 | 1.25 | 0.62 | 0.31 | 0 |
OD | 2.05 | 1.12 | 0.57 | 0.35 | 0.25 | 0.2 | 0.18 | 0.08 |
Corrected OD | 1.97 | 1.04 | 0.49 | 0.27 | 0.17 | 0.12 | 0.1 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Mouse TIMP3 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-101 | 96 |
Plasma(n=8) | 92-105 | 102 |
Tissue Homogenates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Mouse TIMP3 and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Tissue Homogenates(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 89-102 | 87-108 | 105-115 |
Average (%) | 94 | 98 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460