400-0066-400

Mouse Aminoacyl tRNA Synthetase Complex Interacting Multifunctional Protein 1 (AIMP1) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Mouse Aminoacyl tRNA Synthetase Complex Interacting Multifunctional Protein 1 (AIMP1) ELISA Kit
Product Name:

Mouse Aminoacyl tRNA Synthetase Complex Interacting Multifunctional Protein 1 (AIMP1) ELISA Kit

Cat.#:

JL32830

Regulatory Status:
Alternative:

SCYE1; EMAP II; EMAP2; p43; Small Inducible Cytokine Subfamily E,Member 1; Endothelial monocyte-activating polypeptide II; Multisynthase complex auxiliary component p43

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
31.2-2000pg/mL
Sensitivity:
15.3pg/mL
Specificity:
This kit recognizes Mouse AIMP1 in samples. No significant cross-reactivity or interference between Mouse AIMP1 and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Metabolism
  • Mouse Aminoacyl tRNA Synthetase Complex Interacting Multifunctional Protein 1 (AIMP1) ELISA Kit
  • Mouse Aminoacyl tRNA Synthetase Complex Interacting Multifunctional Protein 1 (AIMP1) ELISA Kit
  • Mouse Aminoacyl tRNA Synthetase Complex Interacting Multifunctional Protein 1 (AIMP1) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| AIMP1

Aminoacyl tRNA synthetase complex-interacting multifunctional protein 1 is a protein that is encoded by the AIMP1 gene.The protein encoded by this gene is a cytokine that may be induced by apoptosis and is also released from professional antigen-presenting cells such as dendritic cells. The release of this cytokine renders the tumor-associated vasculature sensitive to tumor necrosis factor. The precursor of SCYE1 (pro-SCYE1) is identical to the p43 subunit, which is associated with the multiaminoacyl-tRNA synthetase complex (mARS). Pro-SCYE1 may function in binding RNA as part of the tRNA synthetase complex in normal cells and in stimulating inflammatory responses after proteolytic cleavage in tumor cells.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 2000 1000 500 250 125 62.5 31.2 0
OD 2.66 2.04 1.51 1.04 0.65 0.39 0.22 0.09
Corrected OD 2.57 1.95 1.42 0.95 0.56 0.3 0.13 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Mouse AIMP1 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 90-105 102
Tissue Homogenates(n=8) 96-108 103





 

| Linearity

Samples were spiked with high concentrations of Mouse AIMP1 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Tissue Homogenates(n=4)
1 : 2 Range (%) 83-95 88-96 90-110
Average (%) 91 93 96
1 : 4 Range (%) 89-103 87-108 105-115
Average (%) 94 101 108







 