400-0066-400

Mouse Cross Linked C-Telopeptide Of Type Ⅰ Collagen (CTXⅠ) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Mouse Cross Linked C-Telopeptide Of Type Ⅰ Collagen (CTXⅠ) ELISA Kit
Product Name:

Mouse Cross Linked C-Telopeptide Of Type Ⅰ Collagen (CTXⅠ) ELISA Kit

Cat.#:

JL20123

Regulatory Status:
Alternative:

CTX-I; CTX1;

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.15-10ng/mL
Sensitivity:
0.04ng/mL
Specificity:
This kit recognizes Mouse CTXⅠ in samples. No significant cross-reactivity or interference between Mouse CTXⅠ and analogues was observed.
Sample Type:
serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Metabolism
  • Mouse Cross Linked C-Telopeptide Of Type Ⅰ Collagen (CTXⅠ) ELISA Kit
  • Mouse Cross Linked C-Telopeptide Of Type Ⅰ Collagen (CTXⅠ) ELISA Kit
  • Mouse Cross Linked C-Telopeptide Of Type Ⅰ Collagen (CTXⅠ) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| CTXⅠ

Cross Linked C-Telopeptide Of Type I Collagen (CTXI) has been identified as a reference marker of bone turnover in the blood for fracture risk prediction and osteoporosis treatment monitoring. CTX-1 is released from intact type 1 collagen via cleavage of cathepsin K and can be detected by antibodies against the eight-amino acid sequence EKAHDGGR. C-terminal peptide of type I collagen is one of them.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 10 5 2.5 1.25 0.62 0.31 0.15 0
OD 2.32 1.89 1.4 0.97 0.58 0.37 0.22 0.07
Corrected OD 2.25 1.82 1.33 0.9 0.51 0.3 0.15 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Mouse CTXⅠ spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-105 102
Cell Culture Supernates(n=8) 96-109 105





 

| Linearity

Samples were spiked with high concentrations of Mouse CTXⅠ and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Cell Culture Supernates(n=4)
1 : 2 Range (%) 84-95 88-96 90-110
Average (%) 91 93 96
1 : 4 Range (%) 89-103 87-108 105-115
Average (%) 94 98 108







 