400-0066-400

Mouse Stem Cell Factor Receptor (SCFR; CD117) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Mouse Stem Cell Factor Receptor (SCFR; CD117) ELISA Kit
Product Name:

Mouse Stem Cell Factor Receptor (SCFR; CD117) ELISA Kit

Cat.#:

JL20353

Regulatory Status:
Alternative:

CD117; KIT; C-Kit; PBT; p145 c-Kit; C-Kit Receptor; Tyrosine-Protein Kinase; V-Kit Hardy-Zuckerman 4 Feline Sarcoma Viral Oncogene Homolog; Piebald Trait

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
1.56-100ng/mL
Sensitivity:
0.8ng/mL
Specificity:
This kit recognizes Mouse SCFR;CD117 in samples. No significant cross-reactivity or interference between Mouse SCFR;CD117 and analogues was observed.
Sample Type:
Serum, plasma and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Signal Transduction
  • Mouse Stem Cell Factor Receptor (SCFR; CD117) ELISA Kit
  • Mouse Stem Cell Factor Receptor (SCFR; CD117) ELISA Kit
  • Mouse Stem Cell Factor Receptor (SCFR; CD117) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| SCFR;CD117

Proto-oncogene c-KIT is the gene encoding the receptor tyrosine kinase protein known as tyrosine-protein kinase KIT, CD117 (cluster of differentiation 117) or mast/stem cell growth factor receptor (SCFR).Multiple transcript variants encoding different isoforms have been found for this gene.KIT was first described by the German biochemist Axel Ullrich in 1987 as the cellular homolog of the feline sarcoma viral oncogene v-kit.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 100 50 25 12.5 6.25 3.12 1.56 0
OD 2.31 1.59 0.99 0.6 0.4 0.27 0.19 0.07
Corrected OD 2.24 1.52 0.92 0.53 0.33 0.2 0.12 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Mouse SCFR;CD117 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-105 102





 

| Linearity

Samples were spiked with high concentrations of Mouse SCFR;CD117 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4)
1 : 2 Range (%) 84-96 88-96
Average (%) 91 93
1 : 4 Range (%) 89-103 87-108
Average (%) 94 98







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460
Top