Home > Sandwich ELISA Kits > Mouse Regulated On Activation In Normal T-Cell Expressed And Secreted (RANTES;CCL5) ELISA Kit
Product Name:
Mouse Regulated On Activation In Normal T-Cell Expressed And Secreted (RANTES;CCL5) ELISA Kit
Cat.#:
JL17335
Regulatory Status:
Alternative:
CCL5; SCYA5; SISd; EoCP; Chemokine C-C-Motif Ligand 5; Eosinophil Chemotactic Cytokine; T-cell Specific Protein p288; Small Inducible Cytokine Subfamily A(Cys-Cys)Member 5
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
15.6-1000pg/mL
Sensitivity:
7.2pg/mL
Specificity:
This kit recognizes Mouse RANTES;CCL5 in samples. No significant cross-reactivity or interference between Mouse RANTES;CCL5 and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Immunology
Product Datasheets
| RANTES;CCL5
Chemokine (C-C motif) ligand 5 (also CCL5) is an 8kDa protein composed of 68 amino acids and acts as a classic chemokine or chemokine. CCL5 is proinflammatory chemokine, recruiting leukocytes to the site of inflammation. It is chemotactic for T cells, eosinophils, and basophils, but also for monocytes, natural-killer (NK) cells, dendritic cells and mastocytes. With the help of particular cytokines (i.e., IL-2 and IFN-γ) that are released by T cells, CCL5 also induces the proliferation and activation of certain NK cells to form CHAK (CC-Chemokine-activated killer) cells. It is also an HIV-suppressive factor released from CD8+ T cells .| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (pg/mL) | 1000 | 500 | 250 | 125 | 62.5 | 31.2 | 15.6 | 0 |
OD | 2.1 | 1.86 | 1.36 | 0.94 | 0.57 | 0.36 | 0.25 | 0.09 |
Corrected OD | 2.01 | 1.77 | 1.27 | 0.85 | 0.48 | 0.27 | 0.16 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Mouse RANTES;CCL5 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-101 | 96 |
Plasma(n=8) | 92-105 | 101 |
Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Mouse RANTES;CCL5 and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
Average (%) | 94 | 98 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460