400-0066-400

Mouse Amine Oxidase, Copper Containing 3 (AOC3) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Mouse Amine Oxidase, Copper Containing 3 (AOC3) ELISA Kit
Product Name:

Mouse Amine Oxidase, Copper Containing 3 (AOC3) ELISA Kit

Cat.#:

JL15696

Regulatory Status:
Alternative:

VAP1; HPAO; SSAO; Membrane primary amine oxidase; Vascular Adhesion Protein 1; Semicarbazide-Sensitive Amine Oxidase; Copper-Containing Amine Oxygen Oxidoreductase

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
1.56-100ng/mL
Sensitivity:
0.73ng/mL
Specificity:
This kit recognizes Mouse AOC3 in samples. No significant cross-reactivity or interference between Mouse AOC3 and analogues was observed.
Sample Type:
serum, plasma, tissue homogenates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Immunology
  • Mouse Amine Oxidase, Copper Containing 3 (AOC3) ELISA Kit
  • Mouse Amine Oxidase, Copper Containing 3 (AOC3) ELISA Kit
  • Mouse Amine Oxidase, Copper Containing 3 (AOC3) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| AOC3

Amine oxidase, copper containing 3 (AOC3), also known as vascular adhesion protein (VAP-1) and HPAO is a member of the semicarbazide-sensitive amine oxidase (SSAO; aka primary amine oxidase) family of enzymes and is associated with many vascular diseases. VAP-1 is a type 1 membrane-bound glycoprotein that has a distal adhesion domain and an enzymatically active amine oxidase site outside of the membrane. The AOC3 gene is mapped onto 17q21 and has an exon count of 6.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 100 50 25 12.5 6.25 3.12 1.56 0
OD 2.09 1.54 1.12 0.77 0.48 0.34 0.25 0.09
Corrected OD 2 1.45 1.03 0.68 0.39 0.25 0.16 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Mouse AOC3 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-105 102
Tissue Homogenates(n=8) 96-108 104





 

| Linearity

Samples were spiked with high concentrations of Mouse AOC3 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Tissue Homogenates(n=4)
1 : 2 Range (%) 85-95 88-96 90-110
Average (%) 91 93 96
1 : 4 Range (%) 89-103 87-108 105-115
Average (%) 94 98 108







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460
Top