Product Name:
Mouse Angiotensin I Converting Enzyme (ACE) ELISA Kit
Cat.#:
JL11821
Regulatory Status:
Alternative:
CD143; ACE1; DCP1; ACEI; ACE-I; Kininase II; Angiotensin-Converting Enzyme; Peptidyl-Dipeptidase A; Dipeptidyl Carboxypeptidase 1; Angiotensin-converting enzyme, soluble form
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
15.62-1000pg/mL
Sensitivity:
6.69pg/mL
Specificity:
This kit recognizes Mouse ACE in samples. No significant cross-reactivity or interference between Mouse ACE and analogues was observed.
Sample Type:
serum, plasma, tissue homogenates, cell lysates, cerebrospinal fluid, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Cancer
Product Datasheets
| ACE
Angiotensin-converting enzyme(ACE), is a central component of the renin–angiotensin system (RAS), which controls blood pressure by regulating the volume of fluids in the body. It converts the hormone angiotensin I to the active vasoconstrictor angiotensin II. Therefore, ACE indirectly increases blood pressure by causing blood vessels to constrict. ACE inhibitors are widely used as pharmaceutical drugs for treatment of cardiovascular diseases. Other lesser known functions of ACE are degradation of bradykinin,substance P and amyloid beta-protein.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (pg/mL) | 1000 | 500 | 250 | 125 | 62.5 | 31.25 | 15.62 | 0 |
OD | 2.32 | 1.93 | 1.31 | 0.85 | 0.51 | 0.39 | 0.28 | 0.1 |
Corrected OD | 2.22 | 1.83 | 1.21 | 0.75 | 0.41 | 0.29 | 0.18 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Mouse ACE spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 85-101 | 96 |
Plasma(n=8) | 92-105 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Mouse ACE and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
Average (%) | 94 | 98 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460