400-0066-400

Mouse Golgi Protein 73 (GP73) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Mouse Golgi Protein 73 (GP73) ELISA Kit
Product Name:

Mouse Golgi Protein 73 (GP73) ELISA Kit

Cat.#:

JL20354

Regulatory Status:
Alternative:

bA379P1.3; C9orf155; Chromosome 9 open reading frame 155; Golgi membrane protein 1; Golgi membrane protein GP73; Golgi phosphoprotein 2; Golgi protein 73 kD; Golgi protein 73kD; GOLM 1; GOLM1; GOLM1_HUMAN; GOLPH 2; GOLPH2; GP 73; GP73; PSEC0257

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
12.5-800ng/mL
Sensitivity:
5.64ng/mL
Specificity:
This kit recognizes Mouse GP73 in samples. No significant cross-reactivity or interference between Mouse GP73 and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Cancer
  • Mouse Golgi Protein 73 (GP73) ELISA Kit
  • Mouse Golgi Protein 73 (GP73) ELISA Kit
  • Mouse Golgi Protein 73 (GP73) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| GP73

Golgi membrane protein 1 (GOLM1) also known as Golgi phosphoprotein 2 or Golgi membrane protein GP73 is a protein that is encoded by the GOLM1 gene.Two alternatively spliced transcript variants encoding the same protein have been described for this gene.The Golgi complex plays a key role in the sorting and modification of proteins exported from the endoplasmic reticulum. The protein encoded by this gene is a type II Golgi transmembrane protein. It processes protein synthesized in the rough endoplasmic reticulum and assists in the transport of protein cargo through the Golgi apparatus. The expression of this encoded protein has been observed to be upregulated in response to viral infection.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 800 400 200 100 50 25 12.5 0
OD 2.39 1.92 1.56 1.04 0.74 0.47 0.32 0.07
Corrected OD 2.32 1.85 1.49 0.97 0.67 0.4 0.25 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Mouse GP73 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 85-101 96
Plasma(n=8) 92-105 102
Cell Culture Supernates(n=8) 96-108 104





 

| Linearity

Samples were spiked with high concentrations of Mouse GP73 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Cell Culture Supernates(n=4)
1 : 2 Range (%) 84-96 88-96 90-111
Average (%) 91 93 96
1 : 4 Range (%) 89-103 87-108 105-115
Average (%) 94 98 108







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460
Top