Detection Range:
0.16-10ng/mL
Sensitivity:
0.07ng/mL
Specificity:
This kit recognizes Mouse mTOR in samples. No significant cross-reactivity or interference between Mouse mTOR and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Cancer
Product Datasheets
| mTOR
The mammalian target of rapamycin (mTOR),also referred to as the mechanistic target of rapamycin, and sometimes called FK506-binding protein 12-rapamycin-associated protein 1 (FRAP1), is a kinase that is encoded by the MTOR gene.mTOR is a member of the phosphatidylinositol 3-kinase-related kinase family of protein kinases.mTOR links with other proteins and serves as a core component of two distinct protein complexes, mTOR complex 1 and mTOR complex 2, which regulate different cellular processes.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0.16 | 0 |
OD | 2.56 | 1.45 | 0.8 | 0.48 | 0.33 | 0.23 | 0.2 | 0.08 |
Corrected OD | 2.48 | 1.37 | 0.72 | 0.4 | 0.25 | 0.15 | 0.12 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Mouse mTOR spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Tissue Homogenates(n=8) | 80-101 | 96 |
Cell Lysates(n=8) | 92-105 | 102 |
| Linearity
Samples were spiked with high concentrations of Mouse mTOR and diluted with Universal Diluent to produce samples with values within the range of the assay.Tissue Homogenates(n=4) | Cell Lysates(n=4) | ||
1 : 2 | Range (%) | 84-96 | 88-97 |
Average (%) | 91 | 93 | |
1 : 4 | Range (%) | 89-103 | 87-108 |
Average (%) | 95 | 97 |