Product Name:
Mouse Connective Tissue Growth Factor (CTGF) ELISA Kit
Cat.#:
JL12526
Regulatory Status:
Alternative:
CCN2; HCS24; IGFBP8; NOV2; Insulin-Like Growth Factor-Binding Protein 8; Hypertrophic Chondrocyte-Specific Protein 24; CCN Family Member 2
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.31-20ng/mL
Sensitivity:
0.14ng/mL
Specificity:
This kit recognizes Mouse CTGF in samples. No significant cross-reactivity or interference between Mouse CTGF and analogues was observed.
Sample Type:
serum, plasma, tissue homogenates and other biological fluids
Assay Procedure:

Research Area:
Cardiovascular Biology
Product Datasheets
| CTGF
Connective tissue growth factor (CTGF), also known as CCN2 , is a matricellular protein of the CCN family of extracellular matrix-associated heparin-binding proteins. Members of the CCN protein family, including CTGF, are structurally characterized by having four conserved, cysteine-rich domains. CTGF has important roles in many biological processes, including cell adhesion, migration, proliferation, angiogenesis, skeletal development, and tissue wound repair, and is critically involved in fibrotic disease and several forms of cancers.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 20 | 10 | 5 | 2.5 | 1.25 | 0.62 | 0.31 | 0 |
OD | 2.4 | 1.77 | 1.11 | 0.7 | 0.45 | 0.3 | 0.2 | 0.07 |
Corrected OD | 2.33 | 1.7 | 1.04 | 0.63 | 0.38 | 0.23 | 0.13 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Mouse CTGF spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-103 | 97 |
Plasma(n=8) | 92-105 | 102 |
Tissue Homogenates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Mouse CTGF and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Tissue Homogenates(n=4) | ||
1 : 2 | Range (%) | 85-95 | 88-96 | 90-110 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 89-103 | 89-108 | 105-115 |
Average (%) | 94 | 99 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T