Product Name:
Mouse B-Cell Activating Factor (BAFF;CD257) ELISA Kit
Cat.#:
JL20135
Regulatory Status:
Alternative:
CD257; TNFSF13B; BLYS; TALL1; THANK; TNFSF20; ZTNF4; B lymphocyte stimulator; Tumor Necrosis Factor Ligand Superfamily Member 13B; Dendritic cell-derived TNF-like
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
125-8000pg/mL
Sensitivity:
70.21pg/mL
Specificity:
This kit recognizes Mouse BAFF;CD257 in samples. No significant cross-reactivity or interference between Mouse BAFF;CD257 and analogues was observed.
Sample Type:
serum, plasma, tissue homogenates and other biological fluids
Assay Procedure:

Research Area:
Cell Biology
Product Datasheets
| BAFF;CD257
B-cell activating factor (BAFF) also known as CD257 among other names, is a protein encoded by the TNFSF13B gene.BAFF is also known as B Lymphocyte Stimulator (BLyS) and TNF- and APOL-related leukocyte expressed ligand (TALL-1) and the Dendritic cell-derived TNF-like molecule. BAFF is a cytokine that belongs to the tumor necrosis factor (TNF) ligand family. This cytokine is expressed in B cell lineage cells, and acts as a potent B cell activator. It has been also shown to play an important role in the proliferation and differentiation of B cells.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (pg/mL) | 8000 | 4000 | 2000 | 1000 | 500 | 250 | 125 | 0 |
OD | 2.68 | 1.74 | 1.01 | 0.67 | 0.41 | 0.28 | 0.2 | 0.09 |
Corrected OD | 2.59 | 1.65 | 0.92 | 0.58 | 0.32 | 0.19 | 0.11 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Mouse BAFF;CD257 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-101 | 96 |
Plasma(n=8) | 92-105 | 102 |
Tissue Homogenates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Mouse BAFF;CD257 and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Tissue Homogenates(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 89-103 | 87-107 | 105-115 |
Average (%) | 94 | 98 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460