400-0066-400

Human Bone Morphogenetic Protein 4 (BMP-4) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Bone Morphogenetic Protein 4 (BMP-4) ELISA Kit
Product Name:

Human Bone Morphogenetic Protein 4 (BMP-4) ELISA Kit

Cat.#:

JL10545

Regulatory Status:
Alternative:

BMP2B; BMP2-B; BMP2B1; ZYME; DVR4; Bone morphogenetic protein 2B

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
3.12-200pg/mL
Sensitivity:
1.97pg/mL
Specificity:
This kit recognizes Human BMP4in samples. No significant cross-reactivity or interference between Human BMP4 and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Developmental Biology
  • Human Bone Morphogenetic Protein 4 (BMP-4) ELISA Kit
  • Human Bone Morphogenetic Protein 4 (BMP-4) ELISA Kit
  • Human Bone Morphogenetic Protein 4 (BMP-4) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| BMP4

Bone morphogenetic protein 4 is a protein that in humans is encoded by BMP4 gene.BMP4 is found on chromosome 14q22-q23.BMP4 is a member of the bone morphogenetic protein family which is part of the transforming growth factor-beta superfamily. The superfamily includes large families of growth and differentiation factors. BMP4 is highly conserved evolutionarily. BMP4 is found in early embryonic development in the ventral marginal zone and in the eye, heart blood and otic vesicle.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 200 100 50 25 12.5 6.25 3.12 0
OD 2.49 1.62 0.96 0.53 0.33 0.24 0.2 0.08
Corrected OD 2.41 1.54 0.88 0.45 0.25 0.16 0.12 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human BMP4 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-105 103
Cell Culture Supernates(n=8) 96-108 105





 

| Linearity

Samples were spiked with high concentrations of Human BMP4 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Cell Culture Supernates(n=4)
1 : 2 Range (%) 84-95 88-96 90-110
Average (%) 91 93 96
1 : 4 Range (%) 89-102 87-108 105-114
Average (%) 94 98 107







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460
Top