Human Acetyl - High mobility group box1 (Acetyl-HMGB1) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Acetyl - High mobility group box1 (Acetyl-HMGB1) ELISA Kit
Product Name:

Human Acetyl - High mobility group box1 (Acetyl-HMGB1) ELISA Kit

Cat.#:

JL47571

Regulatory Status:
Alternative:

Acetyl - High mobility group box1

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
78.12-5000pg/mL
Sensitivity:
40pg/mL
Specificity:
This kit recognizes Human Acetyl-HMGB1 in samples. No significant cross-reactivity or interference between Human Acetyl-HMGB1 and analogues was observed.
Sample Type:
Serum, plasma and other biological fluids.
Assay Procedure:
Assay Procedure
Research Area:
Epigenetics
  • Human Acetyl - High mobility group box1 (Acetyl-HMGB1) ELISA Kit
  • Human Acetyl - High mobility group box1 (Acetyl-HMGB1) ELISA Kit
  • Human Acetyl - High mobility group box1 (Acetyl-HMGB1) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| Acetyl-HMGB1

High mobility group box 1 protein, also known as high-mobility group protein 1 (HMG-1) and amphoterin, is a protein that is encoded by the HMGB1 gene.HMG-1 belongs to the high mobility group and contains a HMG-box domain.Like the histones, HMGB1 is among the most important chromatin proteins. In the nucleus HMGB1 interacts with nucleosomes, transcription factors, and histones.[5] This nuclear protein organizes the DNA and regulates transcription.[6] After binding, HMGB1 bends[7] DNA, which facilitates the binding of other proteins. HMGB1 supports transcription of many genes in interactions with many transcription factors. It also interacts with nucleosomes to loosen packed DNA and remodel the chromatin. Contact with core histones changes the structure of nucleosomes.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 5000 2500 1250 625 312.5 156.25 78.12 0
OD 2.15 1.67 1.21 0.85 0.52 0.34 0.21 0.12
Corrected OD 2.03 1.55 1.09 0.73 0.4 0.22 0.09 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human Acetyl-HMGB1 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 80-102 97
Plasma(n=8) 92-105 103





 

| Linearity

Samples were spiked with high concentrations of Human Acetyl-HMGB1 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4)
1 : 2 Range (%) 84-96 87-96
Average (%) 91 93
1 : 4 Range (%) 89-104 87-108
Average (%) 94 98







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460