Product Name:

Human Succinate Dehydrogenase Complex Subunit C (SDHC) ELISA Kit

Cat.#:

JL18242

Regulatory Status:
Alternative:

PGL3; CYB560, SDH3; CYBL; QPs1; Integral membrane protein CII-3; Succinate-ubiquinone oxidoreductase cytochrome B large subunit; Succinate dehydrogenase cytochrome b560

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.312-20ng/mL
Sensitivity:
0.158ng/mL
Specificity:
This kit recognizes Human SDHC in samples. No significant cross-reactivity or interference between Human SDHC and analogues was observed.
Sample Type:
Tissue homogenates, cell lysates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Epigenetics
  • Human Succinate Dehydrogenase Complex Subunit C (SDHC) ELISA Kit
  • Human Succinate Dehydrogenase Complex Subunit C (SDHC) ELISA Kit
  • Human Succinate Dehydrogenase Complex Subunit C (SDHC) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| SDHC

Succinate dehydrogenase complex subunit C, also known as succinate dehydrogenase cytochrome b560 subunit, mitochondrial, is a protein that is encoded by the SDHC gene.This gene encodes one of four nuclear-encoded subunits that comprise succinate dehydrogenase, also known as mitochondrial complex II, a key enzyme complex of the tricarboxylic acid cycle and aerobic respiratory chains of mitochondria. The encoded protein is one of two integral membrane proteins that anchor other subunits of the complex, which form the catalytic core, to the inner mitochondrial membrane. There are several related pseudogenes for this gene on different chromosomes. Mutations in this gene have been associated with pheochromocytomas and paragangliomas.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 20 10 5 2.5 1.25 0.625 0.312 0
OD 2.67 2.05 1.48 0.97 0.67 0.42 0.27 0.09
Corrected OD 2.58 1.96 1.39 0.88 0.58 0.33 0.18 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human SDHC spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Tissue Homogenates(n=8) 91-105 102
Cell Lysates(n=8) 96-108 104





 

| Linearity

Samples were spiked with high concentrations of Human SDHC and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Tissue Homogenates(n=4) Cell Lysates(n=4)
1 : 2 Range (%) 86-96 90-110
Average (%) 93 96
1 : 4 Range (%) 87-108 105-115
Average (%) 98 110







 