Product Name:
Human Polyribonucleotide nucleotidyltransferase 1 (PNPT1) ELISA Kit
Cat.#:
JL12740
Regulatory Status:
Alternative:
PNPT1; OLD35; Polyribonucleotide Nucleotidyltransferase 1; 3'-5' RNA Exonuclease; 3'-5' RNA exonuclease OLD35; Polynucleotide phosphorylase-like protein
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.08ng/mL
Specificity:
This kit recognizes Human PNPT1 in samples. No significant cross-reactivity or interference between Human PNPT1 and analogues was observed.
Sample Type:
Tissue homogenates, cell lysates and other biological fluids
Assay Procedure:

Research Area:
Epigenetics
Product Datasheets
| PNPT1
Polyribonucleotide nucleotidyltransferase 1 also called Polynucleotide Phosphorylase (PNPase) is a bifunctional enzyme with a phosphorolytic 3' to 5' exoribonuclease activity and a 3'-terminal oligonucleotide polymerase activity.That is, it dismantles the RNA chain starting at the 3' end and working toward the 5' end.It also synthesizes long, highly heteropolymeric tails in vivo. It accounts for all of the observed residual polyadenylation in strains of Escherichia coli missing the normal polyadenylation enzyme. The enzyme is encoded by the PNPT1 gene.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0.156 | 0 |
OD | 2.45 | 1.46 | 0.89 | 0.57 | 0.39 | 0.28 | 0.23 | 0.09 |
Corrected OD | 2.36 | 1.37 | 0.8 | 0.48 | 0.3 | 0.19 | 0.14 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human PNPT1 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Tissue Homogenates(n=8) | 90-105 | 102 |
Cell Lysates(n=8) | 96-108 | 104 |
| Linearity
Samples were spiked with high concentrations of Human PNPT1 and diluted with Universal Diluent to produce samples with values within the range of the assay.Tissue Homogenates(n=4) | Cell Lysates(n=4) | ||
1 : 2 | Range (%) | 85-96 | 90-110 |
Average (%) | 92 | 96 | |
1 : 4 | Range (%) | 87-108 | 105-115 |
Average (%) | 98 | 109 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460