Product Name:
Human Oxytocin Receptor (OXTR) ELISA Kit
Cat.#:
JL14568
Regulatory Status:
Alternative:
OT-R
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.15-10ng/mL
Sensitivity:
0.04ng/mL
Specificity:
This kit recognizes Human OXTR in samples. No significant cross-reactivity or interference between Human OXTR and analogues was observed.
Sample Type:
tissue homogenates, cell lysates and other biological fluids
Assay Procedure:

Research Area:
Developmental Biology
Product Datasheets
| OXTR
The oxytocin receptor, also known as OXTR, is a protein which functions as receptor for the hormone and neurotransmitter oxytocin.The oxytocin receptor is encoded by the OXTR gene.The OXTR protein belongs to the G-protein coupled receptor family, specifically Gq, and acts as a receptor for oxytocin. Its activity is mediated by G proteins that activate several different second messenger systems.Oxytocin receptors are expressed by the myoepithelial cells of the mammary gland, and in both the myometrium and endometrium of the uterus at the end of pregnancy. The oxytocin-oxytocin receptor system plays an important role as an inducer of uterine contractions during parturition and of milk ejection.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.62 | 0.31 | 0.15 | 0 |
OD | 2.36 | 1.49 | 0.95 | 0.54 | 0.35 | 0.26 | 0.21 | 0.09 |
Corrected OD | 2.27 | 1.4 | 0.86 | 0.45 | 0.26 | 0.17 | 0.12 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human OXTR spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Tissue Homogenates(n=8) | 84-102 | 97 |
Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human OXTR and diluted with Universal Diluent to produce samples with values within the range of the assay.Tissue Homogenates(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 89-96 | 90-110 |
Average (%) | 94 | 96 | |
1 : 4 | Range (%) | 87-108 | 105-115 |
Average (%) | 98 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460