Product Name:
Human Apolipoprotein A5 (ApoA-5) ELISA Kit
Cat.#:
JL46640
Regulatory Status:
Alternative:
Apo-A5; APOA-V; APOAV; RAP3; Regeneration-associated protein 3
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
12.5-800ng/mL
Sensitivity:
6.73ng/mL
Specificity:
This kit recognizes Human ApoA-5in samples. No significant cross-reactivity or interference between Human ApoA-5 and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Metabolism
Product Datasheets
| ApoA-5
Apolipoprotein A-V is a protein that in humans is encoded by the APOA5 gene on chromosome 11.It is significantly expressed in liver.The protein encoded by this gene is an apolipoprotein and an important determinant of plasma triglyceride levels, a major risk factor for coronary artery disease. It is a component of several lipoprotein fractions including VLDL, HDL, chylomicrons. It is believed that apoA-V affects lipoprotein metabolism by interacting with LDL-R gene family receptors.Considering its association with lipoprotein levels, APOA5 is implicated in metabolic syndrome.The APOA5 gene also contains one of 27 SNPs associated with increased risk of coronary artery disease.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 800 | 400 | 200 | 100 | 50 | 25 | 12.5 | 0 |
OD | 2.22 | 1.56 | 0.92 | 0.63 | 0.42 | 0.25 | 0.18 | 0.08 |
Corrected OD | 2.14 | 1.48 | 0.84 | 0.55 | 0.34 | 0.17 | 0.1 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human ApoA-5 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-101 | 96 |
Plasma(n=8) | 92-105 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human ApoA-5 and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
Average (%) | 94 | 98 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460