Product Name:
Human Occludin (OCLN) ELISA Kit
Cat.#:
JL17256
Regulatory Status:
Alternative:
Tight Junction Protein Occludin TM4 Minus
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
15.6-1000pg/mL
Sensitivity:
7.4pg/mL
Specificity:
This kit recognizes Human OCLN in samples. No significant cross-reactivity or interference between Human OCLN and analogues was observed.
Sample Type:
Tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Signal Transduction
Product Datasheets
| OCLN
Occludin is a transmembrane protein that regulates the permeability of epithelial and endothelial barriers. It was first identified in epithelial cells as a 65 kDa integral plasma-membrane protein localized at the tight junctions. Together with Claudins, and zonula occludens-1 (ZO-1), occludin has been considered a staple of tight junctions, and although it was shown to regulate the formation, maintenance, and function of tight junctions, its precise mechanism of action remained elusive and most of its actions were initially attributed to conformational changes following selective phosphorylation, and its redox-sensitive dimerization.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (pg/mL) | 1000 | 500 | 250 | 125 | 62.5 | 31.2 | 15.6 | 0 |
OD | 2.54 | 1.73 | 1.25 | 0.83 | 0.53 | 0.37 | 0.3 | 0.1 |
Corrected OD | 2.44 | 1.63 | 1.15 | 0.73 | 0.43 | 0.27 | 0.2 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human OCLN spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-101 | 96 |
Plasma(n=8) | 92-105 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human OCLN and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
Average (%) | 94 | 98 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460