Product Name:
Human Tartrate Resistant Acid Phosphatase (TRAP) ELISA Kit
Cat.#:
JL19558
Regulatory Status:
Alternative:
TRAP; TrATPase; Tartrate Resistant Acid Phosphatase; Type 5 acid phosphatase
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
3.12-200ng/mL
Sensitivity:
1.55ng/mL
Specificity:
This kit recognizes Human TRAP in samples. No significant cross-reactivity or interference between Human TRAP and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates and other biological fluids
Assay Procedure:

Research Area:
Metabolism
Product Datasheets
| TRAP
Tartrate-resistant acid phosphatase (TRAP or TRAPase) is a glycosylated monomeric metalloprotein enzyme expressed in mammals. The mechanism of phosphate ester hydrolysis by TRAP is through a nucleophilic attack mechanism, whereby, catalysis occurs with the binding of a phosphate-substrate to the Fe2+ in the active site of TRAP. TRAP expression is increased in certain pathological conditions. These include leukaemic reticuloendotheliosis (hairy cell leukaemia), Gaucher's disease, HIV-induced encephalopathy, osteoclastoma and osteoporosis, and metabolic bone diseases.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 200 | 100 | 50 | 25 | 12.5 | 6.25 | 3.12 | 0 |
OD | 2.51 | 1.96 | 1.24 | 0.72 | 0.46 | 0.3 | 0.22 | 0.09 |
Corrected OD | 2.42 | 1.87 | 1.15 | 0.63 | 0.37 | 0.21 | 0.13 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human TRAP spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-101 | 96 |
Plasma(n=8) | 92-105 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 104 |
| Linearity
Samples were spiked with high concentrations of Human TRAP and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
Average (%) | 94 | 98 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460