Product Name:
Human Microtubule Associated Protein Tau (MAPT) ELISA Kit
Cat.#:
JL34979
Regulatory Status:
Alternative:
DDPAC; FTDP-17; MAPTL; MSTD; MTBT1; MTBT2; PPND; Neurofibrillary tangle protein; Microtubule Associated Protein Tau; Paired helical filament-tau; G Protein Beta1/Gamma2 Subunit-Interacting Factor 1
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
78.12-5000pg/mL
Sensitivity:
29.35pg/mL
Specificity:
This kit recognizes Human MAPTin samples. No significant cross-reactivity or interference between Human MAPT and analogues was observed.
Sample Type:
tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Metabolism
Product Datasheets
| MAPT
The tau proteins (abbreviated from tubulin associated unit[5]) form a group of six highly soluble protein isoforms produced by alternative splicing from the gene MAPT (microtubule-associated protein tau).They have roles primarily in maintaining the stability of microtubules in axons and are abundant in the neurons of the central nervous system (CNS), where the cerebral cortex has the highest abundance.They are less common elsewhere but are also expressed at very low levels in CNS astrocytes and oligodendrocytes.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (pg/mL) | 5000 | 2500 | 1250 | 625 | 312.5 | 156.25 | 78.12 | 0 |
OD | 2.6 | 1.74 | 1.07 | 0.66 | 0.43 | 0.31 | 0.23 | 0.09 |
Corrected OD | 2.51 | 1.65 | 0.98 | 0.57 | 0.34 | 0.22 | 0.14 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human MAPT spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Tissue Homogenates(n=8) | 84-101 | 96 |
Cell Lysates(n=8) | 92-105 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human MAPT and diluted with Universal Diluent to produce samples with values within the range of the assay.Tissue Homogenates(n=4) | Cell Lysates(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
Average (%) | 94 | 98 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460