400-0066-400

Human Collagen Type Ⅰ Alpha 2 (COLⅠα2) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Collagen Type Ⅰ Alpha 2 (COLⅠα2) ELISA Kit
Product Name:

Human Collagen Type Ⅰ Alpha 2 (COLⅠα2) ELISA Kit

Cat.#:

JL34210

Regulatory Status:
Alternative:

COL1-A2; OI4; Collagen Alpha-2(I)chain; osteogenesis imperfecta type IV; Collagen Of Skin,Tendon And bone,Alpha-2 Chain

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.15-10ng/mL
Sensitivity:
0.08ng/mL
Specificity:
This kit recognizes Human COLⅠα2in samples. No significant cross-reactivity or interference between Human COLⅠα2 and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Metabolism
  • Human Collagen Type Ⅰ Alpha 2 (COLⅠα2) ELISA Kit
  • Human Collagen Type Ⅰ Alpha 2 (COLⅠα2) ELISA Kit
  • Human Collagen Type Ⅰ Alpha 2 (COLⅠα2) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| COLⅠα2

Collagen alpha-2(I) chain is a protein that in humans is encoded by the COL1A2 gene.This gene encodes one of the chains for type I collagen, the fibrillar collagen found in most connective tissues. Mutations in this gene are associated with osteogenesis imperfecta, Cardiac-valvular, and Arthrochlasia type Ehlers-Danlos syndrome, idiopathic osteoporosis, and atypical Marfan syndrome. Symptoms associated with mutations in this gene, however, tend to be less severe than mutations in the gene for alpha-1 type I collagen, since alpha-2 is less abundant. Multiple messages for this gene result from multiple polyadenylation signals, a feature shared by most of the other collagen genes.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 10 5 2.5 1.25 0.62 0.31 0.15 0
OD 2.66 2.04 1.51 1.04 0.65 0.39 0.22 0.09
Corrected OD 2.57 1.95 1.42 0.95 0.56 0.3 0.13 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human COLⅠα2 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-105 102
Tissue Homogenates(n=8) 96-108 105





 

| Linearity

Samples were spiked with high concentrations of Human COLⅠα2 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Tissue Homogenates(n=4)
1 : 2 Range (%) 84-95 88-96 90-110
Average (%) 91 93 96
1 : 4 Range (%) 89-103 87-108 105-115
Average (%) 94 98 108







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
420 / 420
96T
1
640 / 640
Top