Product Name:
Human Collagen Type Ⅰ Alpha 1 (COL1α1) ELISA Kit
Cat.#:
JL12281
Regulatory Status:
Alternative:
COL-1A1; COL1-A1; COL1A-1; OI4; Collagen Alpha-1(I)chain
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.15-10ng/mL
Sensitivity:
0.05ng/mL
Specificity:
This kit recognizes Human COL1A1in samples. No significant cross-reactivity or interference between Human COL1A1 and analogues was observed.
Sample Type:
Serum, plasma and other biological fluids
Assay Procedure:

Research Area:
Metabolism
Product Datasheets
| COL1A1
Collagen, type I, alpha 1, also known as alpha-1 type I collagen, is a protein that in humans is encoded by the COL1A1 gene. COL1A1 encodes the major component of type I collagen, the fibrillar collagen found in most connective tissues, including cartilage.Collagen is a protein that strengthens and supports many tissues in the body, including cartilage, bone, tendon, skin and the white part of the eye (sclera). The COL1A1 gene produces a component of type I collagen, called the pro-alpha1(I) chain. This chain combines with another pro-alpha1(I) chain and also with a pro-alpha2(I) chain (produced by the COL1A2 gene) to make a molecule of type I procollagen.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.62 | 0.31 | 0.15 | 0 |
OD | 2.19 | 1.34 | 0.79 | 0.52 | 0.35 | 0.26 | 0.21 | 0.09 |
Corrected OD | 2.1 | 1.25 | 0.7 | 0.43 | 0.26 | 0.17 | 0.12 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human COL1A1 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-101 | 96 |
Plasma(n=8) | 92-105 | 102 |
| Linearity
Samples were spiked with high concentrations of Human COL1A1 and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 |
Average (%) | 91 | 93 | |
1 : 4 | Range (%) | 89-103 | 87-108 |
Average (%) | 94 | 98 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460